Metal Detector METAL SHARK® OCTA

The Cassel metal detector METAL SHARK® OCTA 1800x1800 reduces the rejection of valuable logs. Only logs that pose a real danger to the saw are rejected.

 

We achieve this goal because the METAL SHARK® detects metal throughout the sensor aperture with almost the same sensitivity. Conventional metal detectors find very small nails on the outside of logs. These do not pose apotential danger to the saw. However, big metal parts inside the log are not detected. The new Cassel metal detector detects outside and inside the log the same metal objects. Therefore, logs not posing a potential danger to the saw are not rejected.


TypeMETAL SHARK® OCTA
InstallationConveyor belt, typically horizontal, but every angle is possible.
Sensor head not devidable.
Metal free zoneOver all at least 4 meters
Before/after detectorMoving / vibrating metal = 1,5x aperture height
Power supply230 V / 50 Hz / 1 phase or
115 V / 60 Hz / 1 phase
Power input700 Watts
Surrounding temperature-10...+50 C / 15...120 F
Product temperature-20...+80 C / 0...180 F
Protection classControl unit IP65 (Nema 4x, 12)Sensor head IP54 (Nema 35)
when set up outdoor we suggest an additional protection
Sensor headStainless steel housing, non-corrosive
Control unitMounted to the side of the sensor
(Option: mounting it on a wall with connection cable),
Digital noise filters eliminate undesired signals.
Product effect memory for 120 products
Automatic teach assistant
Digital delay lineYes, to directly control reject devices.Delay and duration adjustable from 0 - 9,990 ms
Belt speed25 - 4.000 mm/sec. (1” - 6,6 feet/sec.)
Measuring principleInductive, balanced coils, Multi-channel-interpretation
Control unitNewest digital technology
Digital noise filter
Digital balancing
Digital temp. drift control
Constant automatic checks
HandlingKeyboard and LC-Display
LEDs for signal amplitude
LEDs for operating status password protection
Output signals metal alarm1x potential-free
Change-over contact (230V/5A)
1x SPS-control 24V/3mA
1x switching output 24V/30mA
Output signals error1x potential-free
Change-over contact (230V/5A)
Input signalsReject synchronization (24V)
Quit metal alarm (24V)
Interface(Optional on demand) RS232, Rs485, Ethernet
Options, accessories
  • Booster type SPD to increase detection performance
  • Xenon warning flash lamp
  • Acoustic alarm
 




© 2008 Cassel Messtechnik GmbH • In Der Dehne 10 • 37127 Dransfeld • Germany
Phone: +49 5502 9115-0 • Fax: +49 5502 9115-32 • E-Mail: info@cassel.de • Internet: http://www.cassel.de